Vacuum Sensor
Vacuum Sensor
The Vacuum Sensor has a pressure range of 0.001 mBar to 100 mBar and can document the temperature level at the SIP phase with its temperature range of -50 to +140 °C. It can be used for various applications within the food and pharmaceutical industry and is especially ideal for low temperature applications such as lyophilization/Freeze drying.
The high quality wireless TrackSense Pro data loggers consist of high resistant stainless steel and offers high-end technology that allows for stable and highly accurate measurements within different thermal processes.
The TrackSense Pro data logger series are equipped with an Interchangeable sensor option, unlocking several measuring parameters:
✓ Temperature
✓ Pressure
✓ Conductivity
✓ Relative humidity
✓ Vacuum
✓ Steam Penetration
The data loggers can easily be activated and read by the Multi reader station and combined with the Sky module for real time data via wireless communication.
Features
– unique interchangeable sensor option
– real-time data option with Sky module
– works in conjunction with the ValSuite® validation & calibration software
– FDA 21 CFR Part 11 compliant
– pressure range of 0.001mBar to 100mBar Absolute
– covers various applications within pharmaceutical, food and medical industries
Sensor with this logger configuration: Vacuum Sensor
Pressure Measuring Range: 0.001 mBar to 100 mBar (-50 to +80°C)
Measuring Principle: Pirani / Electrical Resistance
Sensor Element: Thermal Conductivity Vacuum Gauge / Pt1000
Pressure / Vacuum Accuracy (Calibrated at -10°C):
0,001 – 0,005 mBar: ± 0,0005 mBar
>0,005 – 0,01 mBar: ± 0,003 mBar
>0,01 – 0,025 mBar: ± 0,005 mBar
>0,025 – 0,1 mBar: ± 0,01 mBar
>0,1 – 0,5 mbar: ± 0,05 mBar
>0,5 – 1,0 mBar: ± 0.1 mBar
>1,0 – 5,0 mBar: ± 0.5 mBar
>5,0 – 10 mBar: ± 2 mBar
>10 – 100 mBar: ± 20 mBar
Pressure / Vacuum Sensor Response Time: 0.002 Second
Temperature Measuring Range: -50 to +140 °C (Calibrated -50 to +60°C)
Temperature Accuracy: ± 0.5 °C
Temperature Response Time: <120 Seconds
Logger with this sensor configuration: Pro 3G
Operating Temperature: -50 to + 140 °C
Operating Pressure: 0.0001 mBar to 5 Bar
House Material: 316L Stainless Steel
Diameter: 25 mm
Length: 44 mm
Weight with Battery: 48 Grams
Memory Capacity: 120,000 Data Points / 60,000 Samples
Minimum Sample Rate: 1 Second
Maximum Sample Rate: 24 Hours
Maximum Start Delay: 14 Days
Intrinsically Safe: Ex II1GD Ex ia IIC T3 Ga, -50°C ≤ Tamb ≤ +105°C
Time Accuracy: ± 5 Seconds Per 24 Hours
Battery: TSP Standard Battery